Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
Blood pressures obtained by indirect measurement in conscious dogs
Abstract:
Heart rate and arterial systolic, mean, and diastolic blood pressures were measured indirectly in apparently healthy dogs in clinical situations (examination rooms, cages, or runs) and in 3 groups of abnormal dogs. An electronic automatic sphygmomanometer measured and analyzed arterial pulses (oscillometric method). Apparently healthy dogs had a mean +/- SD heart rate of 134 +/- 32 beats/min and systolic, mean, and diastolic pressures of 144 +/- 27, 110 +/- 21, and 91 +/- 20 mm of Hg, respectively. The mean systolic pressure was significantly higher in hospitalized dogs than in nonhospitalized dogs. When compared with relaxed dogs, playful dogs had a higher mean heart rate. Apprehensive dogs had a higher mean diastolic pressure than did relaxed dogs. The mean heart rate and blood pressures of panting dogs were not significantly different from the mean values from relaxed dogs. Heavier (greater than 18 kg) and older (greater than 2 years) dogs had lower mean heart rates and higher pressures, compared with lighter (less than or equal to 18 kg) and younger (less than or equal to 2 years) dogs. Infection with Dirofilaria immitis had no effect on heart rate and blood pressures when compared with apparently healthy dogs. Dogs with renal failure had a significantly higher mean diastolic pressure and dogs with mitral regurgitation had a significantly lower mean diastolic pressure, compared with apparently healthy dogs.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure