Oxygen and carbon dioxide concentrations in anaesthetic circuits ventilated with an AGA UV 705 in an oxygen consuming
Abstract:
An oxygen consuming an carbon dioxide producing model lung was used for evaluation of anaesthetic circle systems. Two different circles, the AGA metal circle and the AGA Monosorb circle ventilated by an AGA UV-705 were tested with reference to inspired oxygen concentrations and end-tidal CO2 levels. Carbon dioxide is dependent on alveolar ventilation and CO2 production and thus was stable throughout the experiments. The oxygen concentration of inspired gas decreased progressively with decreasing fresh gas flow. When using the fresh gas inlet on the ventilator outlet block, the inspired oxygen concentration fell 8% as compared to using the fresh gas inlet in the circle. Fresh gas flows under 3 1/min should only be used with oxygen monitoring in the circle. The fresh gas inlet must be directly into the circle, and not in the ventilator outlet block, to avoid hypoxia.
More Related Videos
Related Concept Videos
Gas Exchange and Transport
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Oxygen Transport in the Blood
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...