Related Experiment Video
Updated: Jan 26, 2026

Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
A removable extraluminal Doppler probe for continuous monitoring of changes in cardiac output
Abstract:
To address the problem of monitoring cardiac output in postoperative cardiac patients, a removable, extraluminal pulsed Doppler probe has been constructed which continuously reflects changes in cardiac output by monitoring blood velocity in the ascending aorta. Velocity is related to the frequency of the Doppler shift and the angle at which the ultrasound beam intersects the vessel. A 1 mm2 piezoelectric crystal mounted at a 45 degree angle on the tip of the probe is activated with a 20-MHz range-gated pulsed Doppler, and velocity is determined from Fourier analysis of quadrature data using computer software with a 50-KHz processing range. The device is designed for application to the ascending aorta at the conclusion of a cardiac surgical procedure; and, since mean diameter changes in the ascending aorta have been shown to be very small over a wide range of mean aortic pressures, cardiac output is linearly related to velocity. To test this technique, simultaneous recordings were made from the pulsed Doppler probe and an electromagnetic flow probe in five mongrel dogs over a range of cardiac outputs from 0.5 to 6 l/min for a total of 136 data points. Excellent correlation was found between the electromagnetic flow probe and pulsed Doppler probe data (average r = .98 +/- .006). Average slope between the two was 1.004 and average zero intercept was -0.025 l/min. The catheter is small, stable, has no baseline drift, and continuously and accurately reflects pulsatile changes at high and low flows.
Related Concept Videos
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...

