Related Experiment Video
Updated: Jul 30, 2026

Free Radicals in Chemical Biology: from Chemical Behavior to Biomarker Development
Published on: April 15, 2013
Selective reactions in the analytical characterisation of steroids by gas chromatography-mass spectrometry
Abstract:
The analytical characterization, by GC-MS, of individual compounds in mixtures of steroids, such as occur frequently in biological extracts, is difficult because of the close similarities in structure and properties of many components. The improved separating power of capillary (open-tubular) columns alleviates the problem, but does not solve it fully: for example, the coincidence of retention times of two different compounds may still be virtually complete. Comparative analyses on two distinctively different phases afford one valuable application of selectivity, but may not always be feasible when costly columns are required. Comparative analyses of the sample, before and after effecting its modification by well-defined reactions, are inexpensive and are particularly when selective transformations are used. The use of the microbial enzyme cholesterol oxidase as a selective oxidant for 3 beta-hydroxysteroids (chiefly limited to 4-ene, 5-ene and 5 alpha-types) is illustrated for a model mixture of androstanols related to the boar pheromone (5 alpha, 16-androsten-3 alpha-ol). Retention regularities and changes in mass spectra enhance the reliability of identifications. An exploratory application of cholesterol oxidase in the analysis of minor "polar" sterols in human serum is reported. Most of the known minor sterols are good substrates for the enzyme, and their transformation products yield distinctive GC-MS data, as exemplified for the 7 alpha- and 7 beta-hydroxycholesterols. Another convenient and versatile selective reagent is methaneboronic acid, which yields cyclic esters of suitably constituted diols. These derivatives have shorter retention times (on "non-polar" phases) than the di-TMS ethers, chiefly by virtue of their much lower molecular weights. The mass spectra of cyclic boronates generally show clear molecular ions, also fragmentations that complement the information obtainable from the di-TMS ethers. These features are illustrated for a group of diols and triols of the 5 alpha-pregnane series.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...