Related Experiment Videos
Bentiromide:xylose test in healthy cats
American Journal of Veterinary Research
|December 1, 1982
Summary
The bentiromide:xylose test assesses pancreatic and intestinal function in cats. High individual variations in plasma PABA and xylose levels suggest limited diagnostic use and differences from canine values.
Area of Science:
- Veterinary Medicine
- Gastroenterology
- Diagnostic Testing
Background:
- Pancreatic exocrine insufficiency and intestinal malabsorption are common in cats.
- Accurate diagnostic tests are crucial for effective treatment.
- The bentiromide:xylose test is a combined diagnostic tool for these conditions.
Purpose of the Study:
- To evaluate the bentiromide:xylose test for simultaneous assessment of pancreatic exocrine and intestinal absorptive function in healthy cats.
- To establish reference plasma concentrations of PABA and xylose in feline subjects.
Main Methods:
- Eight clinically healthy cats were administered an oral solution of bentiromide and D-xylose.
- Plasma concentrations of p-aminobenzoic acid (PABA) and xylose were measured at timed intervals post-administration.
- Peak plasma concentrations and individual variations were analyzed.
Main Results:
- Peak plasma PABA concentrations occurred between 60-120 minutes (mean 7.5 ± 3.2 µg/ml at 90 min).
- Peak plasma xylose concentrations occurred between 30-120 minutes (mean 42.6 ± 17.8 mg/dl at 60 min).
- Significant individual variations in plasma PABA and xylose levels were observed in healthy cats.
Conclusions:
- The bentiromide:xylose test shows considerable inter-individual variability in healthy cats, potentially limiting its diagnostic utility.
- Established interpretation guidelines for this test in dogs are not applicable to cats due to lower observed values.