Related Experiment Video
Updated: Aug 10, 2026

Bioassays for Monitoring Insecticide Resistance
Published on: December 30, 2010
Concentration and movement of diazinon in air
Abstract:
Airborne concentrations of diazinon were measured in rooms for 21 days after crack and crevice application. Residue levels were largest in treated rooms (38 micrograms/m3) after application, followed by adjacent (1 microgram/m3) and upper and lower rooms (ca. 0.4 microgram/m3). Low levels of diazinon were detected in all rooms 21 days after application. Small amounts of diazinon (corrected to an 8 min application period) were detected on respirator pads (2.6 microgram) and waist pads (2.3 microgram) worn by the applicator.
Related Concept Videos
Diazonium Group Substitution with Halogens and Cyanide: Sandmeyer and Schiemann Reactions
Diazonium Group Substitution: –OH and –H