The arterial system characterised in the time domain
Cardiovascular Research
|May 1, 1980
Summary
The arterial system
Area of Science:
- Cardiovascular physiology
- Biomedical engineering
- Hemodynamics
Background:
- The arterial tree's characteristics can be understood through its impulse response.
- Reflections within the arterial system significantly impact pressure wave propagation.
Purpose of the Study:
- To characterize the arterial tree using its impulse response to flow.
- To identify and locate distinct reflection sites within the arterial system.
Main Methods:
- An impulse of flow was applied to the arterial system using an occluder around the ascending aorta.
- The resulting pressure (impulse response) was analyzed to identify peaks and decay patterns.
- Pulse wave velocity was used to calculate the location of reflection sites.
Main Results:
- The impulse response exhibited an initial peak, exponential decay (diffuse reflections), and two superimposed peaks (distinct reflections).
- Distinct reflection sites were located distally to the brachiocephalic/subclavian arteries and the descending aorta.
- Vasodilation/vasoconstriction affected diffuse reflections but not the location of distinct reflection sites.
Conclusions:
- The impulse response provides a detailed characterization of the arterial tree, including windkessel properties and reflection sites.
- Distinct arterial reflections are linked to specific anatomical locations and can be identified using pulse wave velocity.
- Pharmacological interventions primarily influence diffuse reflections, highlighting the stability of major reflection sites.