A comparison of aerosol sampling techniques: "open" versus "closed-face" filter cassettes
Summary
Closed-face filter cassettes may underestimate worker exposure to aerosols by excluding larger particles. Open-face sampling generally yielded higher concentrations, indicating potential gravimetric bias in industrial hygiene assessments.
Area of Science:
- Industrial Hygiene
- Occupational Health
- Environmental Science
Background:
- Standard industrial hygiene practice often employs closed-face filter cassettes for aerosol sampling.
- Concerns exist regarding potential gravimetric bias between open-face and closed-face sampling methods.
- Aerosol characteristics and sampling techniques can influence exposure assessment accuracy.
Purpose of the Study:
- To investigate gravimetric bias between open-face and closed-face aerosol sampling methods.
- To evaluate the impact of sampling technique on measured aerosol concentrations across various types.
Main Methods:
- A two-phase field study utilizing paired breathing zone samples.
- Phase I focused on industrial paint spray mist; Phase II examined wood dust, grain dust, cellulose, Portland cement, perlite, welding fumes, and chromic acid mist.
- Both open-face and closed-face 37 mm, 3-piece filter cassettes were used for sample collection.
Main Results:
- Open-face sampling consistently resulted in higher aerosol concentrations than closed-face sampling, except for cellulose dust.
- Data suggests closed-face sampling (4.0 mm inlet) may exhibit size selectivity against larger particles.
- This size selectivity could lead to underestimation of total worker aerosol exposure.
Conclusions:
- The closed-face sampling method may underestimate worker exposure to aerosols due to particle size bias.
- Industrial hygienists should consider the potential limitations of closed-face sampling for certain aerosols.
- Further research is warranted to refine aerosol sampling techniques for accurate exposure assessment.