Evidence of a ventilation-perfusion mismatch during acute unilateral pulmonary artery occlusion in broilers
Related Experiment Video
Updated: Oct 7, 2026

Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
1Department of Poultry Science, University of Arkansas, Fayetteville 72701, USA.
Abstract:
A ventilation-perfusion (V/Q) mismatch can be diagnosed when a moderate increase in cardiac output (CO) causes systemic hypoxemia, thereby exposing a pulmonary incapacity to fully oxygenate the additional blood flowing through the pulmonary vasculature. The susceptibility of broiler chickens to hypoxemia was evaluated in lightly anesthetized, clinically healthy, 40- to 49-d-old males. A snare placed around one pulmonary artery permitted acute, reversible shunting of the entire CO through the unobstructed lung. Blood samples were withdrawn from arterial and venous cannulas for blood gas analysis, and a pulse oximeter was used for noninvasive measurements of the percentage saturation of hemoglobin with oxygen in arterialized capillary beds. The partial pressure of oxygen in arterial blood averaged 103 mm Hg during control periods, 79 mm Hg (hypoxemia) when the pulmonary artery snare was tightened for 12 min, and 101 mm Hg within 5 min after releasing the snare. The percentage saturation of hemoglobin with oxygen before, during, and after tightening the snare averaged, respectively, 96, 91, and 96% for arterial blood, 81, 55, and 78% for venous blood, and 87, 67, and 88% for arterialized capillary beds. Tightening the snare increased the partial pressure of carbon dioxide and the hydrogen ion concentration above control levels in both arterial and venous blood, and these variables returned to control levels upon release of the snare. The combined data constitute direct evidence that clinically healthy broiler chickens are susceptible to hypoxemia during an acute moderate (approximately twofold) increase in pulmonary blood flow.
More Related Videos
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Atelectasis II: Pathophysiology