Related Experiment Video
Updated: Aug 16, 2026

OLIgo Mass Profiling (OLIMP) of Extracellular Polysaccharides
Published on: June 21, 2010
Capillary and slab gel electrophoresis profiling of oligosaccharides
Abstract:
Capillary electrophoresis with laser-induced fluorescent detection, a one-dimensional version of the well-established planar analytical method of polyacrylamide gel electrophoresis, has been proven to be a powerful new microanalytical method for profiling complex carbohydrates. In this paper a comparison is presented between the planar high concentration polyacrylamide gel electrophoresis method and capillary electrophoresis of different carbohydrates with respect to performance and efficiency. N-Linked oligosaccharides were released from several glycoproteins, including fetuin, human immunodeficiency virus (HIV) envelope recombinant glycoprotein (GP-120), alpha 1-acid glycoprotein and ribonuclease B, using recombinant peptide-N-glycosidase F (PNGase F). Both separation methods involve labeling of the released carbohydrates at the reducing end with the fluorescent dye, disodium 8-amino-1,3,6-naphthalene trisulfonate (ANTS). Fluorophore labeling was followed by separation of the labeled oligosaccharides either by high concentration polyacrylamide gel electrophoresis or capillary electrophoresis.
More Related Videos
Related Concept Videos
Oligosaccharide Assembly
Multiple sugar molecules that may or may...
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Southern Blot
Denatured DNA fragments must be transferred onto a carrier membrane from the gel to make it accessible to a probe - a small ssDNA fragment complementary to the target DNA...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Electrophoresis: Overview
There...

