Abstract:
The effects of two post-acquisition corrections on the visual and quantitative analysis of technetium-99m hexamethylpropylene amine oxime (HMPAO) single-photon emission tomography (SPET) were determined. The corrections were for: (1) the improper spatial orientation of the patient data sets, and (2) the non-linear uptake of HMPAO across the blood-brain barrier. Reorienting the SPET image data sets removed observers' uncertainty in assessment caused by suspected head tilt; however, it increased their uncertainty due to perceived subtle perfusion deficits. Applying the correction to compensate for the decrease in uptake of HMPAO in high-flow regions resulted in an increase in the number of positive assessments. In a study involving 30 patient studies, intra-observer reliability increased from 62% to 83% (average of two observers) after applying both of the corrections, while inter-observer reliability improved from 62% to 81%. Quantitative methods of analysing the images are also affected by the corrections. In an ROI-based classification scheme, the quantitative assessments of more than one-half of the images are affected by the two corrections. These results need to be considered when comparing both quantitative and visual results from different studies in which the corrections may or may not have been applied.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET