Using tracheal pressure to trigger the ventilator and control airway pressure during continuous positive airway pressure decreases work of breathing
Related Experiment Video
Updated: Aug 15, 2026

Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
G Messinger1, M J Banner, P B Blanch
1Department of Anesthesiology, University of Florida College of Medicine, Gainesville, USA.
Study Objective:
We evaluated the difference in work of breathing (WOB) during spontaneous ventilation with continuous positive airway pressure (CPAP) among three methods of triggering the ventilator: conventional pressure triggering, tracheal pressure triggering, and flow-by triggering.
Methods:
In an in vitro model of the respiratory system consisting of a bellows (lungs) in a plastic canister (chest wall), spontaneous ventilation was simulated with a piston-driven pump (respiratory muscles). Data were recorded during CPAP of 5 cm H2O (model 7200ae ventilator, Puritan-Bennett, Overland Park, Kan) at peak sinusoidal inspiratory flow rate demands of 60 and 80 L/min and airway resistances of 5 and 20 cm H2O/L/s, with the demand flow system triggered by conventional pressure, tracheal pressure, or flow. Under each condition, tidal volume, pressure-time product (PTP), WOB, and changes in intrapleural pressure (Ppl) and airway pressure were recorded in real time by means of a computerized portable respiratory monitor (model CP-100, Bicore, Irvine, Calif). The Ppl was measured from within the canister, tidal volume by positioning a flow sensor between the Y-piece of the breathing circuit and the endotracheal tube (ETT), and airway pressure from a catheter attached to the flow sensor. The WOB was calculated by the monitor in real time.
Results:
Changes in Ppl were greatest with conventional pressure triggering, less with flow-by triggering, and least with tracheal pressure triggering. The WOB was significantly lower (approximately 50%) with tracheal pressure triggering than with the other two methods. With tracheal pressure triggering only, an effect similar to that of pressure support ventilation (PSV) occurred, which accounted in part for the significant decrease in WOB. The PTP/breath ratio correlated strongly and was a good predictor of WOB (r2 = 0.95).
Conclusions:
Compared with conventional pressure and flow-by methods, triggering with tracheal pressure decreased WOB significantly. This method of triggering may improve patient-ventilator interaction.
More Related Videos
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
04:16Inspiratory Muscle Training as an Adjunct to the Treatment of Weaning Failure in Critically Ill Patients: A Practical Guide
Published on: January 30, 2026
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Cardiopulmonary Resuscitation II: ACLS Airway Management