A robust single-shot partial sampling scheme

P M Glover1, P F Tokarczuk, R W Bowtell

  • 1Magnetic Resonance Centre, University of Nottingham, United Kingdom.

Magnetic Resonance in Medicine
|July 1, 1995
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Tracking head movement inside an MR scanner using electromagnetic coils.

Heliyon·2024
Same author

Feasibility of tracking involuntary head movement for MRI using a coil as a magnetic dipole in a time-varying gradient.

Magnetic resonance imaging·2023
Same author

Acute myocardial infarction: susceptibility-weighted cardiac MRI for the detection of reperfusion haemorrhage at 1.5 T.

Clinical radiology·2016
Same author

Magnetic field effects on the vestibular system: calculation of the pressure on the cupula due to ionic current-induced Lorentz force.

Physics in medicine and biology·2012
Same author

Interaction of MRI field gradients with the human body.

Physics in medicine and biology·2009
Same author

Water proton T1 measurements in brain tissue at 7, 3, and 1.5 T using IR-EPI, IR-TSE, and MPRAGE: results and optimization.

Magma (New York, N.Y.)·2008
Same journal

Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging.

Magnetic resonance in medicine·2026
Same journal

A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp-Logan.

Magnetic resonance in medicine·2026
Same journal

7T 3D-EPI PCASL With High SNR Efficiency and Robustness to Through-Plane B<sub>0</sub> Field Gradients.

Magnetic resonance in medicine·2026
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
See all related articles

This study introduces a novel reduced data acquisition method for image reconstruction. It generates high-quality biological images using significantly less data, nearly matching fully sampled results.

Area of Science:

  • Medical Imaging
  • Image Reconstruction
  • Data Acquisition

Background:

  • Image reconstruction typically requires extensive data, increasing acquisition time and cost.
  • Current methods may face limitations in speed and resolution trade-offs.

Purpose of the Study:

  • To develop and validate a novel method for reducing data requirements in image reconstruction.
  • To achieve high-definition biological images with significantly less sampled data.

Main Methods:

  • Acquiring fully sampled low spatial frequency data up to a cutoff frequency.
  • Sampling alternate lines for higher spatial frequencies.
  • Developing an algorithm to unwrap aliased data and enhance a low-pass image.

Main Results:

Related Experiment Videos

  • Two images are generated: one low-definition and one high-definition but aliased.
  • The algorithm successfully unwraps aliased data for image enhancement.
  • Resulting biological images are nearly indistinguishable from those acquired with complete data sets.

Conclusions:

  • The proposed reduced sampling technique significantly lowers data requirements for image reconstruction.
  • This method provides a viable approach for obtaining high-quality biological images efficiently.
  • The technique offers a promising solution for improving speed and reducing resource demands in imaging.