Development of a process-FIA system using mediator-modified enzyme electrodes

B Gründig1, B Strehlitz, H Kotte

  • 1Institut für Chemo- und Biosensorik, Westfälische Wilhelms-Universität Münster, Germany.

Journal of Biotechnology
|December 1, 1993
PubMed
Summary

A novel computer-controlled flow injection analysis (FIA) system with self-adapting dilution capabilities was developed for real-time bioprocess monitoring. This system enhances sensor adaptability to varying analyte concentrations in industrial bioprocesses.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Generation and characterization of quinolone-specific DNA aptamers suitable for water monitoring.

Biosensors & bioelectronics·2015
Same author

A nitrite sensor based on a highly sensitive nitrite reductase mediator-coupled amperometric detection.

Analytical chemistry·2011
Same author

[Non-specific idiopathic myocarditis (Fiedler's) with congestive heart failure].

Cincinnati journal of medicine·2010
Same author

FluMag-SELEX as an advantageous method for DNA aptamer selection.

Analytical and bioanalytical chemistry·2005
Same author

A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer.

Biosensors & bioelectronics·1999
Same author

Highly sensitive determination of hydrogen peroxide and peroxidase with tetrathiafulvalene-based electrodes and the application in immunosensing.

Biosensors & bioelectronics·1997

Area of Science:

  • Biotechnology
  • Analytical Chemistry
  • Process Monitoring

Background:

  • Industrial bioprocesses require precise real-time monitoring for optimal control and yield.
  • Traditional monitoring systems often struggle with dynamic analyte concentration ranges.
  • Enzyme electrodes offer sensitive detection but can be limited by sample matrix effects and concentration variability.

Purpose of the Study:

  • To develop an automated, computer-controlled flow injection analysis (FIA) system for real-time monitoring of industrial bioprocesses.
  • To enhance the adaptability of analytical sensors to varying analyte concentrations within bioprocesses.
  • To enable self-calibration and real-time dilution for improved analytical performance.

Main Methods:

  • Development of a single-line FIA system utilizing mediator-modified enzyme electrodes.

Related Experiment Videos

  • Modification of the FIA system by replacing the mixing coil with a flexible operating sample dilution unit.
  • Implementation of automated procedures for self-calibration, real-time dilution, and recalibration based on analyte concentration.
  • Main Results:

    • The developed FIA system demonstrated automatic self-calibration, real-time dilution, and recalibration capabilities.
    • The system successfully adapted to a wide range of analyte concentrations, showcasing dynamic range flexibility.
    • The technique was validated for glucose monitoring during microbial fed-batch production of gluconic acid.

    Conclusions:

    • The computer-controlled FIA system with a flexible dilution unit provides an adaptable and automated solution for real-time bioprocess monitoring.
    • The self-adapting nature of the system overcomes limitations associated with fluctuating analyte concentrations.
    • This technology holds significant potential for improving process control and efficiency in industrial biotechnology applications.