Electrocardiographic pseudo-infarct patterns after implantation of cardioverter-defibrillators
S Osswald1, M Roelke, S S O'Nunain
1Cardiac Unit, Massachusetts General Hospital, Harvard Medical School, Boston 02114.
Abstract:
Postoperative electrocardiographic (ECG) changes are frequently present after insertion of implantable cardioverter-defibrillators (ICD) and may mimic perioperative myocardial infarction (MI). The purpose of this study was to assess the incidence and clinical significance of postoperative ECG changes in relation to clinical, laboratory, and implantation data. In 25 (16%) of 156 patients undergoing ICD implantation, significant ECG changes (> or = 50% reduction in R-wave amplitude in > or = 3 leads or new Q waves in > or = 2 leads) were present 1 to 3 days after the operation and persisted at hospital discharge in 12 (8%). Presence of thoracotomy, the total number of induced ventricular fibrillation episodes, and the number of defibrillation shocks required during defibrillation threshold (DFT) testing correlated with postoperative ECG changes. Other factors associated with a significant R-wave loss in the lateral precordial leads included left-sided pleural effusion, lung infiltrates or atelectasis, and large defibrillator patch electrodes over the left ventricle or the lateral chest wall. Myocardial necrosis documented by elevated cardiac enzymes occurred in 6 (5%) of 151 patients without significant ECG changes and in 3 (12%) with (p value not significant). However, postoperative ECG changes associated with elevated enzymes were indistinguishable from changes unrelated to necrosis. Therefore the sensitivity and specificity of the surface ECG for detection of MI after ICD placement is poor. Multiple factors such as thoracotomy, myocardial injury from DFT testing, electric insulation, or shielding of the heart may contribute to the development of electrocardiographic pseudo-infarct patterns.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias