Calibration of endoscopic images
1Department of Surgery, Robert Wood Johnson Medical School, Camden, New Jersey.
The Annals of Otology, Rhinology, and Laryngology
|January 1, 1995
Summary
Pediatric airway surgery requires accurate endoscopic measurements. This study developed a calibration method to correct optical distortion in Storz-Hopkins systems, significantly improving measurement accuracy.
Area of Science:
- Medical Imaging
- Pediatric Surgery
- Optical Engineering
Background:
- Accurate endoscopic evaluation is crucial for pediatric airway surgery.
- Current methods lack objective and reproducible measurement capabilities.
Purpose of the Study:
- To define optical effects of the Storz-Hopkins system.
- To develop a calibration and measurement method for endoscopic images.
Main Methods:
- Geometric images (grids, circles) were viewed and recorded using the Storz-Hopkins system.
- Morphometric analysis with a computer image analyzer was performed.
- Endoscope distortion was quantified as a function of distance from the field center.
Main Results:
- Endoscope distortion was identified, ranging from 0% to 25% shrinkage.
- A mathematical correction factor was derived using the distortion data.
- Measurement error decreased from 17.6% to 4.3% (p < .003) after calibration.
Conclusions:
- Optical distortion in bronchoscopes can be calibrated using morphometric programs.
- This calibration enables accurate measurement of endoscopic images in pediatric airway surgery.
Related Concept Videos
Glassware Calibration
1.5K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.5K
Instrument Calibration
782
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
782
Calibration Curves: Correlation Coefficient
5.0K
In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
5.0K
Plotting and Calibrating the Root Locus
482
Root loci often diverge as system poles shift from the real axis to the complex plane. Key points in this transition are the breakaway and break-in points, indicating where the root locus leaves and reenters the real axis. The branches of the root locus form an angle of 180/n degrees with the real axis, where n is the number of branches at a breakaway or break-in point.
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
482
Calibration Curves: Linear Least Squares
4.5K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
For data that follow a straight line, the standard method for fitting is the linear...
4.5K
Endoscopic Studies II: Thoracocentesis
1.5K
Thoracentesis(Thoracocentesis), commonly known as pleural tap, is a medical procedure where a 22 gauge needle is inserted into the pleural space, the area between the lung and chest wall. This procedure is commonly performed to diagnose or treat various respiratory disorders.
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
1.5K