Quantitative bremsstrahlung single photon emission computed tomographic imaging: use for volume, activity, and
J A Siegel1, L S Zeiger, S E Order
1Department of Radiation Oncology, Cooper Hospital/University Medical Center, Camden, NJ 08103.
Purpose:
To perform bremsstrahlung single photon emission computed tomographic (SPECT) imaging using 32P chronic phosphate for volume and activity quantitation to calculate absorbed dose estimates.
Methods And Materials:
Seven cancer patients enrolled in clinical Phase I therapeutic protocols were injected with 2.5 million particles of macroaggregated albumin, followed by colloidal 32P chromic phosphate by direct interstitial injection into the tumor-bearing region under computed tomographic (CT) guidance. SPECT images were obtained in these patients. The patient body contour was defined through the use of two externally placed Compton backscatter 99mTc sources. A computer algorithm was written to facilitate region-of-interest volume and activity determination on the reconstructed SPECT slices based on a fixed threshold method. Three sequential SPECT studies were acquired in two of these patients, to determine the accuracy of activity quantitation for bremsstrahlung SPECT studies using Chang's postprocessing method of attenuation compensation with a computer-generated body contour based on the Compton backscatter sources, and an experimentally measured effective linear attenuation coefficient for 32P. The serial data in these two patients were used to calculate absorbed dose estimates.
Results:
The 99mTc backscatter sources enabled the patient body outline to be clearly visualized in all the transaxial reconstructed slices and did not contribute significant counts to the patient 32P counts. The calculated activities from the SPECT studies were within 7.8% of the administered 32P activity. The two calculated patient absorbed doses were 4.2 x 10(3) Gy and 5.9 x 10(3) Gy for injected activities of 736 MBq and 920 MBq, respectively.
Conclusion:
We conclude that accurate quantitative bremsstrahlung SPECT imaging, for the case of high contrast well-localized activity distributions, with a commercially available postprocessing attenuation correction algorithm, can be performed in a clinical setting. Entirely SPECT-based measurements can be used to generate absorbed dose estimates.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Biological Effects of Radiation
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET