Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Simultaneous transcranial Doppler and arterial blood pressure response to lower body negative pressure
R L Bondar1, M S Kassam, F Stein
1Canadian Space Agency, Ottawa.
Abstract:
Microgravity induces fluid shifts which can alter the cardiovascular responses of astronauts both during space flight and on return to Earth. The decrease in orthostatic tolerance in astronauts returning from a weightless environment can be modelled in ground-based studies using lower body negative pressure (LBNP). This study examined the physiological changes induced by LBNP and determined a reliable method of predicting the onset of presyncope to enable evaluation of countermeasures for loss of orthostatic tolerance, such as glycerol-induced hyperhydration. Six healthy male subjects, aged 18 to 45 years, were each subjected to two LBNP tests, with or without glycerol ingestion. Continuous, non-invasive measurements of middle cerebral artery blood flow velocities (CBF) by transcranial Doppler, arterial blood pressure (Finapres ABP), ECG and LBNP box pressures were recorded during each test. Negative pressure was increased in three minute intervals until symptoms of presyncope were observed. An increase in heart rate (HR), a relatively constant mean ABP and a steady decline in mean CBF were consistently observed as the box pressure was decreased. The continuous on-line measurements clearly showed consistent dynamic changes in both CBF and ABP waveforms in response to changes in LBNP. At the onset of presyncope, sudden drops in mean ABP, HR and mean CBF were typically noted, the latter providing the earliest indication of presyncope. The time required to re-establish original baseline values of CBF and ABP after release of box pressure varied widely from six to over ten minutes.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure