Myocardial uptake and kinetic properties of technetium-99m-Q3 in dogs
M C Gerson1, R W Millard, A J McGoron
1Department of Internal Medicine, Eugene L. Saenger Radioisotope Laboratory, University of Cincinnati, Ohio 45267.
Unlabelled:
We postulated that 99mTc-Q3, a cationic imaging agent, produces myocardial activity related to myocardial blood flow during myocardial ischemia and pharmacologic coronary artery vasodilation, and shows little or no myocardial redistribution over 4 hr after intravenous injection.
Methods:
In six Group 1 dogs, the chest was opened, the left circumflex coronary artery was acutely ligated, and dipyridamole (0.32, 0.56 or 0.84 mg/kg) was infused into the right atrium, followed by 10 mCi of 99mTc-Q3. Myocardial blood flow was measured by radiolabeled microspheres. The animals were euthanized and 357 myocardial samples were assayed in a well counter for 99mTc activity. One week later, radiolabeled microsphere activity was counted and myocardial blood flow calculated. In nine Group 2 dogs, a variable occluder was placed around the left circumflex coronary artery and an ischemic level of circumflex blood flow was maintained constant over 4 hr as measured by an ultrasonic flow meter. Dipyridamole (0.56 mg/kg) was then infused into the right atrium followed by 10 mCi of 99mTc-Q3. Gamma camera images were acquired at 5, 15, 30, 60, 120 and 240 min following 99mTc-Q3 injection. Microsphere blood flow and endocardial biopsies (n = 6 dogs) were performed at 30, 60, 120 and 240 min following 99mTc-Q3 injection.
Results:
In the Group 1 animals, 99mTc activity (y) was related to myocardial blood flow (x) from 0 to 6.1 ml/min/g by the relationship y = 0.83X + 0.18, r = 0.95, p = 0.0001. The scintigraphic ratio of myocardial perfusion defect zone counts-to-normal myocardial zone counts (0.54 +/- 0.05 at 30 min) remained constant over 4 hr, as did technetium counts from direct endocardial sampling. Scintigraphic count ratios allowed discrimination between perfusion defect and normal myocardial regions beginning at 5 min following 99mTc-Q3 injection.
Conclusions:
Over a range of myocardial blood flows from 0 to 6.1 ml/min/g, 99mTc-Q3 myocardial activity is related to myocardial flow at the time of tracer injection. Technetium-99m-Q3 shows no evidence of myocardial redistribution over a 4-hr period.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT