Related Experiment Video
Updated: Aug 2, 2026

Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol
Published on: September 7, 2018
Utility of magnetization prepared GRE MRI for the detection of focal liver lesions
T C Winter1, P C Freeny, H V Nghiem
1Department of Radiology, University of Washington Medical Center, Seattle 98195.
Abstract:
We compared the efficacy of rapidly acquired magnetization prepared gradient-echo (MP-GRE) sequences with CT and standard MRI pulse sequences for the detection of focal liver lesions. Fourteen patients with 28 focal liver lesions were scanned. TI times of 300, 450, and 600 ms were used. MP-GRE lesion conspicuity was compared to corresponding CT, T1, T2, T2-post-superparamagnetic-iron-oxide (SPIO), and STIR images. It was found that the differences between MP-GRE and CT and MP-GRE and T1 MRI were not significant. However, overall anatomic detail was better with CT and T1 MRI than MP-GRE. Lesion conspicuity was significantly worse with the MP-GRE than with the T2, T2-post-SPIO, and STIR sequences (all p values = 0.00). Maximal liver signal nulling occurred at TI = 300 ms in 13 out of 14 patients. However, the T1 for optimal focal liver lesion conspicuity varied widely and could not be predicted before scanning. No new lesions were seen on the MP-GRE sequence that could not be seen on the CT or standard MRI sequences. As currently implemented, MP-GRE imaging offers no advantage in the detection of focal liver lesions over CT and standard MRI pulse sequences.
Insights
Magnetization prepared gradient-echo (MP-GRE) sequences do not improve detection of focal liver lesions compared to CT and standard MRI. MP-GRE showed significantly worse lesion conspicuity than other MRI sequences.
Area of Science:
- Radiology
- Medical Imaging
- Hepatology
Background:
- Focal liver lesions require accurate detection for effective management.
- Standard MRI sequences and CT scans are commonly used for liver lesion detection.
- Rapidly acquired magnetization prepared gradient-echo (MP-GRE) sequences are a newer imaging technique.
Purpose of the Study:
- To compare the efficacy of MP-GRE sequences against CT and standard MRI for detecting focal liver lesions.
- To evaluate lesion conspicuity and anatomic detail provided by MP-GRE compared to other modalities.
Main Methods:
- Fourteen patients with 28 focal liver lesions were scanned using MP-GRE sequences with varying inversion times (TI).
- MP-GRE images were compared with CT, T1-weighted MRI, T2-weighted MRI, T2-weighted post-superparamagnetic-iron-oxide (SPIO) MRI, and STIR MRI.
- Statistical analysis was performed to assess differences in lesion conspicuity and anatomic detail.
Main Results:
- MP-GRE showed no significant difference in lesion detection compared to CT and T1 MRI.
- CT and T1 MRI provided superior overall anatomic detail compared to MP-GRE.
- MP-GRE demonstrated significantly worse lesion conspicuity than T2, T2-post-SPIO, and STIR sequences (p=0.00).
- Optimal TI for lesion conspicuity varied and was unpredictable.
- No new lesions were detected with MP-GRE that were not visible on CT or standard MRI.
Conclusions:
- Currently implemented MP-GRE sequences offer no advantage over CT and standard MRI for detecting focal liver lesions.
- MP-GRE sequences are less effective for lesion conspicuity compared to other MRI techniques.
- Further research may be needed to optimize MP-GRE parameters for liver lesion detection.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging

