Modified crossover and guidewire loop technique for double-balloon angioplasty of the aortic bifurcation
A K Gupta1, K Ravimandalam, V R Rao
1Department of Radiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, India.
Cardiovascular and Interventional Radiology
|March 1, 1994
Abstract:
A modified form of crossover railroad technique is described for iliac and aortic bifurcation obstructions in which the iliac occlusion is crossed from the opposite side by a guidewire which is brought out through the ipsilateral puncture site. After forming a loop in the abdominal aorta, dilatation with two balloons is performed. This procedure was successfully performed in 2 patients having iliac artery occlusions and aortic bifurcation obstruction.