Related Experiment Videos
On-line expiratory flow-volume curves during thoracic surgery: occurrence of auto-PEEP
G Bardoczky1, A d'Hollander, J C Yernault
1Department of Anesthesiology, Erasme University Hospital, Free University of Brussels, Belgium.
Abstract:
Flow-volume loops were monitored continuously in 39 patients undergoing thoracic surgery requiring one-lung ventilation. In 26 of the 39 patients (67%), auto-positive end-expiratory pressure (auto-PEEP) was seen on the flow-volume curves during both two-lung and one-lung ventilation. Eighty-seven percent of the patients whose trachea was intubated with a smaller size (35- and 37-French gauge) double-lumen tracheal tube exhibited auto-PEEP, compared with patients in whom the tube used was larger (39- or 41-French gauge: 54% and 50%, respectively). Before operation, mean airway resistance was significantly greater in patients who exhibited auto-PEEP during anaesthesia (2.4 cm H2O litre-1 s) than in patients without auto-PEEP (1.7 cm H2O litre-1 s).