Sources of variation in back and leg dynamometry
A Coldwells1, G Atkinson, T Reilly
1Centre for Sport and Exercise Sciences, Liverpool John Moores University.
Ergonomics
|January 1, 1994
Summary
This study validates a portable dynamometer for measuring back and leg strength, finding it reliable and concurrent with a laboratory device. Strength measurements show variations based on the time of day.
Area of Science:
- Biomechanics
- Kinesiology
- Sports Science
Background:
- Assessing maximal voluntary contraction strength is crucial in clinical and sports settings.
- Portable dynamometers offer a convenient alternative to laboratory-based equipment.
- Evaluating the validity and reliability of new measurement tools is essential.
Purpose of the Study:
- To determine the concurrent validity of the Takei portable dynamometer against a criterion measure (Lido Active).
- To assess the test-retest reliability of the Takei dynamometer for back and leg strength.
- To investigate the influence of time of day on strength measurements using the Takei dynamometer.
Main Methods:
- Concurrent validity was assessed by comparing Takei dynamometer measurements with Lido Active measurements for leg extension and back strength.
- Test-retest reliability was evaluated by measuring back and leg strength twice on the Takei dynamometer with a six-day interval.
- The effect of time of day was examined by measuring strength at six different times over a single day.
Main Results:
- The Takei dynamometer showed significant correlations with the Lido Active for both leg strength (r=0.90) and back strength (r=0.79).
- High test-retest reliability was found for leg strength (r=0.80) and back strength (r=0.91), with no significant difference in leg strength means.
- A significant, though small, difference was observed in back strength means between test and retest, and a time of day effect was noted for both measures.
Conclusions:
- The Takei portable dynamometer demonstrates good concurrent validity and reliability for assessing back and leg strength.
- Measurement protocols should consider the potential influence of time of day on strength outcomes.
- This device is a viable tool for field-based strength assessments.