Related Experiment Videos
[A simple external fixator of Kirschner wires and electric clips for use on fingers]
1Abteilung für Hand- und Plastische Chirurgie, Krankenhaus Bethel, Bückeburg.
Abstract:
A simple external fixator is introduced made of Kirschner wires and electric clips. This external fixator has been used for fifteen years and has a number of indications: phalangeal fractures, infections, and cross-finger flaps.