Non-invasive ambulatory BP monitoring during the night: randomised comparison of different reading intervals
G Schillaci1, P Verdecchia, I Zampi
1Division of Medicine, General Hospital R. Silvestrini, Perugia, Italy.
Abstract:
Frequent measurements of BP during noninvasive monitoring could interfere with sleep, with consequent possible overestimation of nocturnal BP. We performed 24h noninvasive ambulatory BP monitoring (Space-Labs 90207) in 24 patients with essential hypertension twice, 1 week apart. Subjects were instructed to follow, as far as possible, a similar pattern of daily activity during the two sessions. The frequency of daytime readings (from 06.00 to 22.00 h) was kept constant in the two sessions (one every 15 minutes), while that of nocturnal readings (from 22.00 to 06.00 h) varied in random order: every 15 minutes in session A and every 60 minutes in session B. Mean sleep BP did not differ between session A (138/83 mmHg (SD 15/10 mmHg)) and session B (138/83 mmHg (SD 14/10 mmHg)). The percentage reduction of ambulatory SBP and DBP from wake to sleep was 9.7% and 10.0%, respectively, in session A, and 14.0% and 14.1%, respectively, in session B (all P = NS). The duration of sleep was 6.1 hours (SD 2 hours) in session A and 6.0 hours (SD 2 hours) in session B (P = NS). On average, 6.8% of nocturnal readings in session A and 7.6% of nocturnal readings in session B failed to pass the automatic editing criteria, but no hourly interval was lacking in valid measurements on both sessions.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Holter Monitor: 24-Hour Monitoring