[Non-invasive, continuous, portable blood pressure recording in the sleep laboratory]
Related Experiment Video
Updated: Nov 9, 2026

Through-the-Wall Blood Sampling Method to Minimize Sleep Disruption in Clinical Settings
Published on: June 13, 2025
T Penzel1, U Brandenburg, J H Peter
1Zeitreihenlabor, Medizinische Poliklinik, Philipps-Universität Marburg.
Abstract:
The importance of cardiovascular consequences of sleep related breathing disorders implies the need for continuous recording of blood pressure in any cardiorespiratory polysomnography. Invasive techniques, which are the gold standard, are limited to special indications and studies. Non-invasive, continuous methods opened new possibilities for sleep laboratory investigations. The existing Finapres system proved to be a valuable method if parallel video recording was applied. The size of the system restricts its application to stationary settings only. Therefore the methodology was improved and integrated in a portable recorder. A prototype of this recorder, the Portapres, was validated against invasive pressure in 9 one-hour tests during the day and 12 polysomnographic recordings of 8 hours duration. The Portapres has now two finger cuffs and an automatic hydrostatic height compensation to overcome limitations of the Finapres. The technical implementation of the recorder needs more improvements. The correlation of mean blood pressure was 0.81 and mean pressure of the Portapres was 6.8 mmHg lower than invasive values.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment: