Magnetic resonance imaging of transfusional hepatic iron overload
S Bondestam1, A Lamminen, V J Anttila
1Department of Radiology, Helsinki University Central Hospital, Finland.
Abstract:
The transfusional iron overload in 11 adult patients suffering from haematological malignancy was studied in 14 consecutive 1.0 Tesla magnetic resonance imaging (MRI) studies. Routine T1- and T2-weighted spin echo sequences and a fat suppressed sequence (STIR) were used. The ratio from a region of interest of the liver parenchyma and from a manganese chloride reference phantom was measured. There was a definite difference between the signal ratio from the haematological patient group and the control group (p = 0.0001). The patients showed a diminished signal ratio in all pulse sequences used. There was a statistically significant inverse linear correlation between the number of transfused red cell units and the signal ratio in the T1-weighted (p = 0.03) and the T2-weighted (p = 0.03) images. A definite decrease of the effect is found after 20-30 red cell unit transfusions in T2-weighted and STIR images.