Related Experiment Video
Updated: Aug 18, 2026

Cell-based Assay Protocol for the Prognostic Prediction of Idiopathic Scoliosis Using Cellular Dielectric Spectroscopy
Published on: October 16, 2013
Low-dose radiography of scoliosis in children. A comparison of methods
J A Kalmar1, J P Jones, C R Merritt
1Department of Radiology, Ochsner Clinic, New Orleans, Louisiana.
Study Design:
Records of 1,582 conventional and computed radiographic examinations performed to evaluate scoliosis were reviewed and compared to determine differences in total radiation burden.
Objective:
This study evaluated the impact of computed radiographic imaging (CRI) on radiation exposure in children undergoing serial spinal radiographs for scoliosis assessment and compared exposure from CRI with that of low-dose film-screen combinations.
Summary Of Background Data:
CRI permits diagnostic radiographic studies to be performed with a dose reduction of 80%-95% compared to conventional film-screen systems. High speed film-screen systems also permit a significantly lower exposure. Each approach has unique advantages and disadvantages.
Methods:
Over 6 years, we performed 1,582 spinal examinations in children 4-14 years old using reduced dosage techniques with computed radiography. The images were obtained with Fuji FCR 101 and Philips PCR/SP systems. The adequacy of diagnostic image quality in the serial evaluation of scoliosis at different exposure levels was evaluated and compared with regular and film-screen systems with speeds ranging from 250 to 1,200.
Results:
Diagnostic-quality images for evaluating scoliosis can be obtained with doses of 5% or less than required with conventional film-screen systems. Computed radiography provides image quality and dose reduction comparable to a 1,200-speed film-screen system.
Conclusion:
CRI gives satisfactory images at 5% reduction of the standard film-screen dose. Based on comparison with a 1,200 speed film-screen system, CRI provides equal or better image quality at a similar radiation dose. The cost of CRI is higher than for film-screen radiography, but wide latitude and the ability to tailor dose with requirements for image quality are significant advantages for CRI.
More Related Videos
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...