Related Experiment Video
Updated: Aug 15, 2026

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Effect of temperature on finger artery pressure evaluated by volume clamp technique
1Department of Clinical Physiology, Faculty of Health Sciences, University Hospital, Linköping, Sweden.
Abstract:
We examined the effect of temperature on digital arterial blood pressure obtained by continuous beat-to-beat non-invasive monitoring with a volume-clamp technique (Finapres). In 10 normal volunteers and 13 patients with symptoms of vasospasm, digital pressure and brachial artery pressure (cuff method) was simultaneously recorded in control conditions at room temperature, during body cooling, finger heating, and truncal heating. In the control condition digital systolic blood pressure was significantly higher (16.1 +/- 14.2 mmHg) than brachial systolic pressure. The augmentation of digital systolic pressure correlated inversely with finger tip temperature. Diastolic and mean arterial pressure did not differ significantly between the two methods. Body cooling augmented the systolic finger-arm gradient while truncal heating and finger heating had the opposite effect. Finger heating reduced systolic augmentation without changing the mean and diastolic blood pressure. Similar changes were also observed in the patients with vasospasm except in one case with a pronounced Raynaud syndrome where digital blood pressure was lower than brachial artery pressure. We conclude that augmentation of finger systolic pressure seems to be dependent on local vasoconstriction of A/V shunts and that finger heating may be a useful procedure to improve the reliability of Finapres readings.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure

