The influence of teeth on denture base processing accuracy

A D Jackson1, B R Lang, R F Wang

  • 1College of Dentistry, Howard University, Washington, DC.

The International Journal of Prosthodontics
|July 1, 1993
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[ARID1A-deficient endometrial carcinoma: a clinicopathological analysis of five cases].

Zhonghua bing li xue za zhi = Chinese journal of pathology·2026
Same author

[Efficacy of photodynamic therapy in extrahepatic cholangiocarcinoma].

Zhonghua wai ke za zhi [Chinese journal of surgery]·2026
Same author

[Association between childhood trauma and the number of disorders of gut-brain interaction diagnosed in adults, as well as the mediating role of personality disorder traits and anxiety].

Zhonghua yi xue za zhi·2026
Same author

[Advances in constitutional mismatch repair deficiency syndrome associated tumors].

Zhonghua bing li xue za zhi = Chinese journal of pathology·2025
Same author

[The value of differential diagnosis of post-reflux swallow-induced peristaltic wave index between esophageal diseases of gut-brain interaction and gastroesophageal reflux disease].

Zhonghua yi xue za zhi·2024
Same author

[Analysis of the regional distribution differences of common variations of the MMACHC gene in cblC methylmalonic acidemia patients].

Zhonghua er ke za zhi = Chinese journal of pediatrics·2024
Same journal

The Effect of Different Polishing Systems on the Surface Roughness and Color Changes of Monolithic Zirconia Crowns: A Comparison of Additive and Subtractive Manufacturing.

The International journal of prosthodontics·2026
Same journal

Retention and Wear Performance of Locator Attachments Under Cyclic Loading: An In Vitro Study.

The International journal of prosthodontics·2026
Same journal

Use and Interpretation of Patient-Reported Outcome Measures in Randomized Controlled Trials in Prosthodontics.

The International journal of prosthodontics·2026
Same journal

Influence of Implant Angulation on the Accuracy of Complete Arch Digital Scans with Intraoral Photogrammetry.

The International journal of prosthodontics·2026
Same journal

Influence of Virtual Articulator Programming on the Occlusal Contact Pattern in CAD/CAM Crowns: The Role of Jaw Motion Tracking Data.

The International journal of prosthodontics·2026
Same journal

Clinical Performance, Esthetics, and Patient-Rated Outcomes of Porcelain-Fused-to-Metal Fixed Partial Dentures with Cobalt-chromium and Gold-alloy Frameworks: A 5-to-7 Year Retrospective Study.

The International journal of prosthodontics·2026
See all related articles

Denture teeth significantly impact the accuracy of processed denture bases across all tested methods. However, the compression molding technique showed accuracy differences only in denture bases without teeth.

Area of Science:

  • Dental Materials Science
  • Biomaterials Engineering
  • Prosthodontics

Background:

  • Accurate denture fabrication is crucial for patient comfort and function.
  • The influence of denture teeth on the dimensional accuracy of denture bases requires further investigation.
  • Understanding processing method variations is key to optimizing denture base quality.

Purpose of the Study:

  • To evaluate the effect of denture teeth on the accuracy of denture bases processed by three different methods.
  • To compare the accuracy of compression molding, injection pressing, and vacuum-assisted resin pouring techniques.
  • To identify which processing methods are most affected by the presence or absence of denture teeth.

Main Methods:

  • Utilized the Michigan Computer Graphics Coordinate Measuring System for precise measurements.

Related Experiment Videos

  • Processed denture bases using three distinct techniques: compression molding, injection pressing, and vacuum-assisted resin pouring.
  • Assessed dimensional accuracy with and without the inclusion of denture teeth for each processing method.
  • Main Results:

    • The presence of denture teeth was found to influence the accuracy of processed denture bases across all three techniques.
    • Compression molding showed significant accuracy differences in denture bases fabricated without teeth.
    • Injection pressing and vacuum-assisted resin pouring techniques did not exhibit significant accuracy differences related to the presence of teeth.

    Conclusions:

    • Denture teeth presence is a critical factor affecting denture base accuracy, varying by processing method.
    • Compression molding is more susceptible to accuracy deviations when teeth are absent.
    • Injection pressing and resin pouring offer greater dimensional stability irrespective of denture teeth presence.