A comparison of two studies of the pressure distribution under the feet of normal subjects using different equipment
1Section of Molecular Rheumatology, Northwick Park Hospital, Harrow, United Kingdom.
Abstract:
There is growing interest in the use of foot pressure measurement both clinically and in the study of normal subjects. A number of systems are now commercially available, but comparison of the results is complicated by the different techniques employed. This paper compares the results of two studies. The first examined a large group of normal subjects using the dynamic pedobarograph. The second was identical to the first except that the EMED F system was used. The second study was carried out in order to verify existing results and to assess the clinical significance of the expected differences. Comparison of the results from the two studies showed that the median peak pressures demonstrated similar patterns with the highest pressure in the forefoot under the second/third metatarsal heads and the toes taking gradually reduced pressure from the first to the fifth toe. The EMED F showed higher peak pressures than the dynamic pedobarograph under the heel, the medial four metatarsal heads, and the great toe and showed lower peak pressures and shorter contact times under the lateral four toes. The pattern of loading across the metatarsal heads was further analyzed using an objective method of splitting the subjects into groups. Four groups were isolated from both sets of results, and this has confirmed that only a proportion of normal subjects demonstrate highest loading under the first metatarsal head whereas the remainder show highest loading centrally within the forefoot.
More Related Videos
06:35Using Gold-standard Gait Analysis Methods to Assess Experience Effects on Lower-limb Mechanics During Moderate High-heeled Jogging and Running
Published on: September 14, 2017
04:34A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Related Concept Videos
Pulse Assessment Sites
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.