Related Experiment Video
Updated: Aug 21, 2026

Comprehensive Endovascular and Open Surgical Management of Cerebral Arteriovenous Malformations
Published on: October 20, 2017
Percutaneous coil embolization of superfluous vascular connections in patients with congenital heart disease
Insights
Transcatheter coil embolization safely and effectively treats abnormal vascular connections in congenital heart disease patients. This minimally invasive procedure achieved high occlusion rates for various arteriovenous malformations, improving patient outcomes.
Area of Science:
- Cardiology
- Interventional Radiology
- Pediatric Cardiology
Background:
- Congenital heart disease (CHD) often involves complex vascular anomalies.
- Hemodynamically significant vascular connections require effective treatment to prevent complications.
Purpose of the Study:
- To evaluate the safety and efficacy of transcatheter Gianturco coil embolization for treating superfluous vascular connections in patients with CHD.
- To assess occlusion rates and complications associated with the procedure.
Main Methods:
- Transcatheter embolization using Gianturco coils was performed on 26 vascular connections in 19 patients with CHD.
- Vascular connections included aortopulmonary collaterals, pulmonary sequestration vessels, surgical shunts, patent ductus arteriosus, and others.
- Coil-to-vessel diameter ratio and coils used per vessel were recorded.
Main Results:
- Successful occlusion was achieved in 24 of 26 attempts (92%), with complete occlusion in 81% and near-complete occlusion in 12%.
- Two attempts failed due to vessel tortuosity and narrow origins.
- Transient leg pulse decrease occurred in one patient; fever occurred in 21% but resolved without sequelae.
Conclusions:
- Percutaneous coil embolization is a safe and effective treatment for various undesirable vascular connections in CHD.
- The technique offers a high success rate with manageable complications.
Abstract:
Transcatheter Gianturco coil embolization of 26 superfluous but hemodynamically significant vascular connections was attempted in 19 patients with congenital heart disease. There were 18 aortopulmonary collaterals, two vessels involved in pulmonary sequestration, two surgical aortopulmonary shunts (one inadvertently connected from the left subclavian artery to a left upper pulmonary vein), two cases of patent ductus arteriosus, one regurgitant left ventricular-to-descending aorta conduit, and a left superior vena cava-to-left atrium post Fontan procedure. The mean ratio of coil to vessel diameter was 1.6 +/- 0.7, and a mean of 1.5 +/- 1.1 coils were used per vessel. Occlusion was achieved in 24 of 26 attempts (92%), being complete in 21 (81%) and near complete (> 80% decrease in flow) in three (12%). Two attempts failed; a tortuous aortopulmonary collateral was engaged by the delivery catheter but the coil could not be advanced past an acute angle, and another aortopulmonary collateral had a narrow origin and enlarged distally, resulting in coil migration to a distal pulmonary artery branch. One patient had a transient decrease in leg pulses that resolved spontaneously. Fever occurred in four patients (21%) within 12 hours of coil placement, and resolved in all without sequelae or complications. A variety of undesirable vascular connections in patients with congenital heart disease can be safely and effectively treated by percutaneous coil embolization.
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care