Related Experiment Video
Updated: Aug 19, 2026

Technique of Porcine Liver Procurement and Orthotopic Transplantation using an Active Porto-Caval Shunt
Published on: May 7, 2015
Mixed venous oxygen saturation monitoring during liver transplantation
A Steib1, R Gohard, J P Beller
1Service d'anesthésie-réanimation chirurgicale, Hôpitaux Universitaires de Strasbourg, France.
Abstract:
High mixed venous oxygen saturation (SVO2) values due to limited oxygen extraction capacities are reported in some patients with severe liver disease. The aim of this study was to evaluate the usefulness of SVO2 monitoring to assess adequate oxygen supply in such patients scheduled for liver transplantation. Nineteen patients with oxygen extraction ratio below 12% were analysed and compared to 20 patients with a pre-operative ratio over 17%. The two groups were comparable with regard to initial pathology, preload and haemoglobin levels. SVO2 values measured discontinuously by co-oximetry were unaffected by the first part of surgery and the clamping period in patients with low oxygen extraction ratio. In these patients, SVO2 was never correlated to oxygen supply during the whole procedure whereas good correlation was noted before and after unclamping in the other group. Tissue hypoxia detected by a dependent oxygen consumption-oxygen supply relationship occurred at clamping and unclamping in patients with initial low oxygen extraction capacities. It is concluded that expensive SVO2 continuous monitoring may not be effective in reflecting changes in oxygen supply in anaesthetized patients with initial severely impaired oxygen extraction capacity.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...