Related Experiment Video
Updated: Aug 5, 2026

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
A prospective randomised comparison of the dynamic hip screw and the gamma locking nail
P J Radford1, M Needoff, J K Webb
1Department of Fracture and Orthopaedic Surgery, University Hospital, Queen's Medical Centre, Nottingham, UK.
Abstract:
We made a randomised prospective comparison of the Dynamic Hip Screw and the Gamma locking nail for the internal fixation of 200 petrochanteric femoral fractures in elderly patients. There was less intraoperative blood loss and a lower rate of wound complications in the patients treated by the Gamma nail. They had, however, a high incidence of femoral shaft fracture which we relate in part to implant design. We do not recommend the use of the Gamma nail for these fractures.