A tissue compensation source-to-skin measurement system

R G Lane, B R Paliwal, P F Elliot

    Radiology
    |March 1, 1977
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Electron contamination in <sup>6</sup><sup>0</sup> Co gamma-ray beams.

    Medical physics·2018
    Same author

    Time series analyses of breathing patterns of lung cancer patients using nonlinear dynamical system theory.

    Physics in medicine and biology·2011
    Same author

    Wave-front reconstruction using a Shack-Hartmann sensor.

    Applied optics·2010
    Same author

    Verification of tomotherapy dose delivery.

    Journal of medical physics·2010
    Same author

    Phase retrieval with prior information.

    Journal of the Optical Society of America. A, Optics and image science·2008
    Same author

    Modeling scintillation from an aperiodic Kolmogorov phase screen.

    Applied optics·2008

    A new, affordable system accurately measures source-to-skin distance for radiation therapy. This tool aids in precise tissue compensation, enhancing treatment planning across various field sizes and beam angles.

    Area of Science:

    • Medical Physics
    • Radiation Oncology

    Background:

    • Accurate measurement of source-to-skin distance (SSD) is crucial for effective radiation therapy.
    • Tissue compensation techniques require precise SSD data for optimal dose delivery.

    Purpose of the Study:

    • To describe a novel, user-friendly, and cost-effective system for measuring SSD.
    • To evaluate the system's accuracy and precision across diverse treatment parameters.

    Main Methods:

    • Development of a low-cost measurement system for SSD.
    • Validation of measurements for variable treatment field sizes.
    • Testing across multiple treatment beam angles.

    Main Results:

    • The system provides accurate and precise SSD measurements.

    Related Experiment Videos

  • Measurements are reliable irrespective of treatment field size or beam angle.
  • The system is compatible with various tissue compensation strategies.
  • Conclusions:

    • This system offers a practical solution for obtaining essential SSD data in radiation oncology.
    • Its ease of use and low cost make it accessible for diverse clinical settings.
    • The validated accuracy supports its utility in determining tissue compensation requirements.