Related Experiment Video
Updated: Aug 11, 2026

Isolation and Respiratory Measurements of Mitochondria from Arabidopsis thaliana
Published on: January 5, 2018
Oxygen consumption using the K2 telemetry system and a metabolic cart
1Department of Physical Therapy, School of Allied Health Sciences, University of Texas Medical Branch, Galveston 77550.
Abstract:
The purpose of this study was to compare measurements of oxygen consumption (VO2), ventilation (VE), and respiratory rate (RR) between a relatively new portable, telemetry system (K2) and a system that has been shown to be valid and reliable. Duplicate measurements were made at rest and during four levels of exercise in 10 subjects. Heart rate values were comparable for exercise at the same work level during gas collection using the two systems, indicating that the metabolic stresses were similar. Oxygen consumption measurements were significantly lower using the K2 system compared with a metabolic measurement cart (MMC). There was no significant difference in VE, but RR was lower for measurements made with the MMC. Compared with the MMC, the K2 system uses a slightly different formula to calculate VO2 because the content of carbon dioxide in expired air is not measured. To determine differences resulting from the method of calculating VO2, MMC measurements were applied to the formula used by the K2 system, and K2 values were adjusted using the RER values obtained from the MMC. There were no differences between these calculated values and the values obtained directly from either the MMC or the K2 system. Consequently, we concluded that the lower VO2 values obtained with the K2 system were attributed to the method of collecting and analyzing expired air, rather than to the method of calculating VO2.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Transport in the Blood
Metabolic Rate
The Basal Metabolic Rate (BMR) measures the energy expended at rest.
Several factors influence the...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Requirements and Growth Patterns

