A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
In-hospital experience with multiprogrammable implantable antitachycardia/antifibrillation devices
B Waldecker1, J Brachmann, C Schmitt
1Department of Medicine III, University of Heidelberg, Germany.
Programmable internal defibrillators offer safe and effective control for malignant ventricular tachycardia and fibrillation. Device programmability and flexibility were clinically useful in managing these serious heart rhythm disorders.
Area of Science:
- Cardiology
- Biomedical Engineering
Background:
- Refractory malignant ventricular tachycardia (VT) and fibrillation (VF) pose significant risks.
- Automatic internal defibrillators (AIDs) are crucial for managing these arrhythmias.
- The role of multiprogrammable AIDs with antitachycardia pacing (ATP) requires further clinical evaluation.
Purpose of the Study:
- To assess the clinical safety and utility of multiprogrammable AIDs with and without ATP in patients with refractory VT/VF.
- To evaluate the impact of device programmability on arrhythmia detection and therapy delivery.
Main Methods:
- Implantation of 60 multiprogrammable AIDs in patients with refractory VT/VF.
- Individual adjustment of VT/VF detection parameters based on arrhythmia type and incidence.
- Programmability allowed for pre-discharge device function verification.
Main Results:
- No increased surgical or postoperative risks associated with complex AID systems.
- Tailored detection parameters and reduced shock energy for VT vs. VF.
- Antitachycardia pacing was well-tolerated in 68% of eligible patients.
- Device programmability facilitated verification of correct tachyarrhythmia control decisions.
Conclusions:
- Multiprogrammable AIDs with flexibility in programming are clinically safe and useful for managing malignant ventricular arrhythmias.
- Further long-term studies are needed to confirm persistent efficacy and safety.
- Individualized programming enhances the therapeutic potential of AIDs.
More Related Videos
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management
Dysrhythmias VI: Management of Dysrhythmias
Cardiomyopathy V: Interprofessional Care