Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Contour resolution of the EyeSys Corneal Analysis System

J A Young1, J H Talamo, I M Siegel

  • 1Department of Ophthalmology, Massachusetts Eye & Ear Infirmary, Harvard Medical School, Boston 02114, USA.

Journal of Cataract and Refractive Surgery
|July 1, 1995
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

On the Use of Belladonna in Cholera.

Chicago medical examiner·2023
Same author

Morphology, histochemistry and physiology of the major salivary glands in the echidna Tachyglossus aculeatus (Monotremata).

Journal of morphology·2018
Same author

Trends in body image of adolescent females in metropolitan and non-metropolitan regions: a longitudinal study.

BMC public health·2016
Same author

The applied model of imagery use: Examination of moderation and mediation effects.

Scandinavian journal of medicine & science in sports·2015
Same author

Reduction in gastric cancer surgical mortality over 10 years: An adverse events analysis.

Annals of medicine and surgery (2012)·2015
Same author

Preoperative C-reactive protein predicts the severity and likelihood of complications following appendicectomy.

Annals of the Royal College of Surgeons of England·2014

The EyeSys videokeratography instrument accurately measures corneal contour. Its contour resolution of +/- 0.0047 mm offers significant clinical value for eye care professionals.

Area of Science:

  • Ophthalmology
  • Biomedical Engineering
  • Optometry

Background:

  • Accurate measurement of corneal contour is crucial for diagnosing and managing various eye conditions.
  • Conventional videokeratography instruments provide valuable data for corneal topography.
  • Assessing the precision of these instruments is essential for reliable clinical application.

Purpose of the Study:

  • To evaluate the accuracy of the EyeSys videokeratography instrument for measuring corneal contour.
  • To determine the contour resolution achievable with the EyeSys system and its specialized software.
  • To ascertain the clinical utility of the EyeSys instrument based on its measurement precision.

Main Methods:

  • Utilized the EyeSys Corneal Analysis System, a conventional videokeratography device.

Related Experiment Videos

  • Employed manufacturer-developed specialized software for contour data analysis.
  • Measured seven calibrated spheres to assess instrument accuracy and resolution.
  • Main Results:

    • A consistent contour resolution of +/- 0.0047 mm was achieved across all tested spheres.
    • This resolution represents a 95% confidence interval for the measurements.
    • The obtained contour resolution indicates high precision in measuring corneal shape.

    Conclusions:

    • The EyeSys videokeratography instrument demonstrates high accuracy in measuring corneal contour.
    • The achieved contour resolution is sufficient for significant clinical value in ophthalmology and optometry.
    • The EyeSys system, with its specialized software, is a reliable tool for corneal topography analysis.