Related Experiment Videos
Vicryl-mesh wrap for the implantation of hydroxyapatite orbital implants: an animal model
D R Jordan1, A Ells, S Brownstein
1University of Ottawa Eye Institute, Ont.
Objective:
To evaluate host fibrovascularization of hydroxyapatite orbital implants wrapped in sclera or in Vicryl (polyglactin 910) mesh in a rabbit model.
Numbers:
Eight adult New Zealand white rabbits that received hydroxyapatite orbital implants wrapped in homologous donor sclera (four animals) or Vicryl mesh (four animals).
Interventions:
The rabbits had one eye enucleated and then received a 12-mm hydroxyapatite implant wrapped in sclera or Vicryl mesh. Magnetic resonance imaging (MRI) and bone scintigraphy were done to assess host fibrovascularization of the implant 4, 8, 12 and 20 weeks after implantation. Two animals (one in each group) were killed at each of these times, and the implant was removed for histopathological examination.
Main Outcome Measures:
Enhancement on MRI, uptake on bone scintigraphy, fibrovascularization seen on histopathological examination.
Results:
The degree of fibrovascularization was substantial in all the specimens but appeared greater in the Vicryl-mesh-wrapped implants in the first 12 weeks after implantation on both histopathological and MRI studies. At 20 weeks these findings were similar in the two groups. A granulomatous foreign-body giant-cell reaction to both the Vicryl mesh and the implant itself was present up to 8 weeks after implantation. Bone scans showed only grade 1+ activity in all the implants.
Conclusions:
Host fibrovascularization in the rabbit appears to occur to a greater degree in Vicryl-mesh-wrapped hydroxyapatite implants than in those wrapped in donor sclera during the first 12 weeks after implantation. Vicryl mesh appears to be an acceptable alternative wrap for the hydroxyapatite implant, eliminating the need for donor sclera and its potential risks of transmissible diseases.