Related Experiment Video
Updated: Aug 11, 2026

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Determinants of systolic pressure variation in patients ventilated after vascular surgery
M Beaussier1, P Coriat, A Perel
1Department of Anesthesiology and Intensive Care, Pitié Hospital, Paris, France.
Objective:
To discover the predominant determinant of systolic pressure variation during positive-pressure ventilation in mechanically ventilated patients after a vascular surgical procedure.
Design:
Case control study.
Setting:
Postanesthesia care unit at a university hospital.
Participants:
Eleven patients who were sedated during mechanical ventilation after abdominal aortic surgery.
Interventions:
Radial arterial pressure and airway pressure were simultaneously recorded. The systolic pressure variation was measured as the mean difference between the maximal and minimal systolic pressure values during five consecutive mechanical breaths. The delta down was measured as the difference between the systolic blood pressure during apnea and the minimal values of the systolic pressure after one mechanical breath. The velocity time integral, which is closely related to stroke volume, was measured throughout the systolic pressure measurements.
Measurements And Main Results:
Positive correlation was found between changes in velocity time integral and the magnitude of both systolic pressure variation (r = 0.73) and delta down (r = 0.80). Volume loading did not significantly modify systolic blood pressure. However, it did not significantly decrease systolic pressure variation and delta down. The corresponding changes in velocity time integral provoked by mechanical ventilation decreased significantly as well.
Conclusions:
The decrease in systolic pressure provoked by positive-pressure inspiration reflects simultaneous decreases in stroke volume. This suggests that a decrease in left ventricular filling, associated with positive-pressure inspiration, is responsible for systolic pressure variation. This finding confirms the interest in considering systolic pressure variation to provide reliable information about the responsiveness of the heart to preload variations.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...