Related Experiment Video
Updated: Jul 11, 2026

Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
High-precision D/H measurement from hydrogen gas and water by continuous-flow isotope ratio mass spectrometry
H J Tobias1, K J Goodman, C E Blacken
1Division of Nutritional Sciences, Cornell University, Ithaca, New York 14853, USA.
Abstract:
Two instrumental approaches are described for continuous-flow high-precision determinations of D/H ratios from hydrogen gas or via on-line reduction of water. In the first system, Ar is used as a carrier gas, with a Ni reduction furnace and a water trap to remove minor levels of unreduced water that are a potential source of memory effects. Precisions of SD < 10/1000 (delta DSMOW) over a 600/1000 range from -55 to +532/1000 are obtained for liquid water (0.4 microL). Linearity is excellent over 4 orders of magnitude of D concentration in tap water (r2 > 0.9999), although precision degrades at enrichments delta DSMOW > 5000/1000. In the second system, a heated Pd metal foil functions as a filter to admit purified hydrogen into the mass spectrometer. Hydrogen gas injections are made into flowing Ar and are directed to the Pd filter (approximately 330 degrees C) which passes hydrogen isotopes only while diverting the carrier flow to waste. Precisions of these measurements are SD < 6/1000 over the D enrichment range -213 to 340/1000, with excellent linearity (r2 > 0.9999) and accuracy (< 2/1000). Similar precision is obtained using the on-line reduction apparatus and a water trap prior to the Pd filter with injections of 0.4 microL of liquid water, with acceptable linearity (r2 > 0.999) over 3 orders of magnitude of D concentration. Neither system shows any sign of memory effects when water is analyzed. The data indicate that either one of these systems is a useful means for continuous-flow IRMS of D/H isotope ratio determinations.
Related Concept Videos
¹H NMR of Labile Protons: Deuterium (²H) Substitution
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometry: Isotope Effect
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...

