A comparison of current regulations and regulatory guide governing quality control of dose calibrators
1Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, MN 55905, USA.
Abstract:
The U.S. Nuclear Regulatory Commission recently amended its regulation governing the calibration of dose calibrators. The changes include (1) the radioactivity of radiopharmaceutical dosages that contain photon-emitting radionuclides has to be measured by a dose calibrator prior to administration to patients and human research subjects; (2) the lower end of the radioactivity limits for linearity testing has been raised to 1.1 MBq (30 microCi) to be consistent with the Nuclear Regulatory Commission Quality Management Program Requirements; and (3) the requirement for signature of the Radiation Safety Officer on the records for accuracy, linearity, and geometry dependence tests has been removed. Although these are practical amendments, further clarification of the new Nuclear Regulatory Commission regulation is required for the following issues: (1) inconsistency in individual's identification requirement for the record keeping (i.e., initials of the individual who performed the constancy check and identity of the operator for the accuracy, linearity, and geometry dependence tests); (2) whether the use of 99mTc is adequate for linearity testing when other radionuclides are being measured in the dose calibrator; and (3) lack of provision for dose calibrator adjustment when conducting the accuracy test. In addition, Nuclear Regulatory Commission Regulatory Guide 10.8 should be revised to become consistent with the Nuclear Regulatory Commission's regulation in order to assist licensees with full compliance of the requirements or recommendations.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Dosage Regimens: Designs and Approaches
Dosage Regimen: Individualization