Related Experiment Video
Updated: Aug 15, 2026

Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
Thrombus imaging using technetium-99m-labeled high-potency GPIIb/IIIa receptor antagonists. Chemistry and initial
D A Pearson1, Lister-James, W J McBride
1Chemistry Department, Diatide, Inc., Londonderry, New Hampshire 03053, USA.
Abstract:
Platelet-specific compounds which are radiolabeled with gamma-emitting radionuclides may be particularly useful for the noninvasive in vivo detection of thrombi. The synthesis of peptides which are potent inhibitors of platelet aggregation and which contain a chelator for the radionuclide technetium-99m are described. The target compounds were designed such that stable, oxotechnetium(V) species could be prepared where the site of metal coordination was well defined. A strategy was employed where the pharmacophore-Arg-Gly-Asp-(RGD), or RGD mimetic, was constrained in a ring which was formed by the S-alkylation of a cysteine residue with an N-terminal chloroacetyl group. Binding affinities were enhanced by the replacement of arginine with the arginine mimetics S-(3-aminopropyl)cysteine and 4-amidinophenylalanine. Further enhancements could be obtained by the synthesis of oligomers which contained two or more rings containing receptor binding regions. The increase in binding affinity seen was more than that expected from a simple stoichiometric increase of pharmacophore. The most potent compounds described had IC50s of approximately 0.03 microM for the inhibition of human platelet aggregation. Two of the more potent peptides (P280 and P748) were labeled with technetium-99m and assessed in a canine thrombosis model. The 99m Tc complexes of the peptides prepared in this work hold promise as thrombus imaging agents due to their high receptor binding affinity, ease of preparation, and expected rapid pharmacokinetics.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT

