Related Experiment Video
Updated: Jul 15, 2026

Real Time Measurements of Membrane Protein:Receptor Interactions Using Surface Plasmon Resonance (SPR)
Published on: November 29, 2014
Tracer kinetic modelling of receptor data with mathematical metabolite correction
1Division of Nuclear Medicine, Department of Radiology, University Hospital, Ramistrasse 100, CH-8091 Zurich, Switzerland.
Abstract:
Quantitation of metabolic processes with dynamic positron emission tomography (PET) and tracer kinetic modelling relies on the time course of authentic ligand in plasma, i.e. the input curve. The determination of the latter often requires the measurement of labelled metabolites, a laborious procedure. In this study we examined the possibility of mathematical metabolite correction, which might obviate the need for actual metabolite measurements. Mathematical metabolite correction was implemented by estimating the input curve together with kinetic tissue parameters. The general feasibility of the approach was evaluated in a Monte Carlo simulation using a two tissue compartment model. The method was then applied to a series of five human carbon-11 iomazenil PET studies. The measured cerebral tissue time-activity curves were fitted with a single tissue compartment model. For mathematical metabolite correction the input curve following the peak was approximated by a sum of three decaying exponentials, the amplitudes and characteristic half-times of which were then estimated by the fitting routine. In the simulation study the parameters used to generate synthetic tissue time-activity curves (K1-k4) were refitted with reasonable identifiability when using mathematical metabolite correction. Absolute quantitation of distribution volumes was found to be possible provided that the metabolite and the kinetic models are adequate. If the kinetic model is oversimplified, the linearity of the correlation between true and estimated distribution volumes is still maintained, although the linear regression becomes dependent on the input curve. These simulation results were confirmed when applying mathematical metabolite correction to the [11C]iomazenil study. Estimates of the distribution volume calculated with a measured input curve were linearly related to the estimates calculated using mathematical metabolite correction with correlation coefficients >0.990. However, the slope of the regression line displayed considerable variability among the subjects (0.33-0.95), demonstrating that absolute quantitation of the distribution volume was impaired. Mathematical metabolite correction is a feasible method and may prove useful in cases where actual metabolite data cannot be obtained. The potential for absolute quantitation seems limited, but the method allows the quantitative assessment of regional ratios of receptor measures.
Related Concept Videos
Pharmacokinetic Models: Overview
There are three primary types of models: empirical, compartment, and physiological. Empirical models, with minimal assumptions,...
Fundamental Mathematical Principles in Pharmacokinetics: Calculus and Graphs
On the other hand, integral calculus focuses on...
Mechanistic Models: Compartment Models in Individual and Population Analysis
Physiological Pharmacokinetic Models: Assumption with Protein Binding
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Nonlinear Pharmacokinetics: Michaelis-Menten Equation
Vmax represents the maximum achievable process rate, while KM, known as the Michaelis constant, signifies the drug concentration at which the process rate reaches half its maximum. This relationship between Vmax, KM, and Cp gives rise to three distinct...

![Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58491.jpg&w=3840&q=50)