Related Experiment Video
Updated: Jul 24, 2026

Utilizing Electroencephalography Measurements for Comparison of Task-Specific Neural Efficiencies: Spatial Intelligence Tasks
Published on: August 9, 2016
Comparison of a frequency-based analysis of electroencephalograms (Z-ratio) and visual scoring on the multiple sleep
C L Albertario1, S M Zendell, G Hertz
1Winthrop-University Hospital Sleep Disorders Center, Mineola, New York 11501, USA.
Abstract:
In a sample of multiple sleep latency test naps following nocturnal polysomnograms from a group of 13 patients of varying ages and diagnoses, we compared a computer-derived electroencephalographic (EEG) measure (z-ratio) with standard visual sleep stage scoring. In this clinical population, z-ratio scoring agreed with human scorers approximately 80% of the time when determining sleep versus wake in 30-second epochs. These results show that a single, objectively quantifiable value derived from a single channel of EEG can distinguish between sleep and wakefulness (as defined by Rechtschaffen and Kales) with at least a moderate degree of precision. When refined, the z-ratio method might be of use as the basis for a new sleep scoring system, particularly where an accurate determination of sleep onset is required.