Related Experiment Video
Updated: Aug 15, 2026
![Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F50301.jpg&w=3840&q=50)
Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
Simultaneous determination of gastric emptying and intestinal absorption during cycle exercise in humans
G P Lambert1, R T Chang, D Joensen
1Department of Physiology, University of Iowa, Iowa City, USA.
Abstract:
Because fluid absorption values derived from intestinal perfusion may not represent intestinal absorption of the same solution following its oral ingestion, the present study measured intestinal absorption following oral ingestion of a beverage. To do so required the simultaneous determination of gastric emptying. Seven males positioned a nasogastric tube in the gastric antrum and a multilumen tube in the duodenum under fluoroscopic guidance. Gastric emptying (GE) and intestinal water flux (WF) were measured during 85 min of cycle exercise at 60.6 +/- 3.7% VO2max (x +/- SE) in a 22 degrees C environment. Subjects ingested a total of 23 ml.kg-1 body weight (2005 +/- 187 ml) of a 6% isotonic carbohydrate-electrolyte solution by drinking 396 +/- 34 ml 5 min prior to exercise followed by 198 +/- 17 ml every 10 min during exercise. Mean stomach volume (312 +/- 80 ml) and GE (19.7 +/- 2.0 ml.min-1) did not change significantly after the initial 35 min equilibration period. Mean WF during oral ingestion of the solution (19.5 +/- 2.6 ml.cm-1.h-1) did not differ significantly from mean WF (16.4 +/- 1.9 ml.cm-1.h-1) during perfusion of the same solution directly into the duodenum at a rate equal to each subject's GE rate. Total solute flux (mmol.cm-1.h-1) was not different between drinking (4.1 +/- 1.3) and infusion (3.8 +/- 1.0) trials, nor were the changes in plasma volume. Urine production immediately following the exercise bout was unchanged between drinking (89.1 +/- 27.5 ml) and perfusion (88.5 +/- 24.2) experiments. These data indicate that: 1) relatively constant stomach volumes can be maintained over a prolonged period of time and can produce relatively constant GE rates, and 2) intestinal absorption of an isotonic carbohydrate-electrolyte beverage can be accurately determined by a modified segmental perfusion technique employing ingestion rather than intestinal perfusion.
More Related Videos
Related Concept Videos
Intestinal Phase of Digestion
The arrival of the chyme in the small intestine distends the duodenum, which triggers the enterogastric reflex. This distension...
Gastric Emptying
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems related to...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...

