Lack of reliability in Conconi's heart rate deflection point
1Chelsea School Research Centre, University of Brighton, Eastbourne, East Sussex, United Kingdom.
Abstract:
Conconi et al. (1982) reported the development of noninvasive field test for anaerobic threshold (AT) based upon an observed deviation from the linear heart rate (HR)--running velocity (RV) relationship at high RV (HRdev). While the validity of the Conconi test has been debated (Heck and Hollmann 1992; Tokmakidis and Leger 1992), the reliability of the Conconi test has never been independently assessed in athletes performing the protocol outlined by Conconi. This study evaluated the reliability of the Conconi test in 15 well-trained male distance runners (22.5 +/- 3.3 yrs, 67.7 +/- 4.8 kg, VO2 peak 66.4 +/- 4.8 ml.kg-1.min-1) who performed a treadmill simulation of the Conconi test protocol twice within a 4-8 day period. The results were as follows: 6 subjects demonstrated HRdev in both Conconi tests, 5 subjects demonstrated HRdev in only one test, and in 4 subjects HRdev could not be discerned in either test. It was concluded that failure to determine a reproducible HRdev by subjective assessment in 9 of 15 subjects makes the Conconi test unsuitable for reliable evaluation of AT.
More Related Videos
05:48Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
Published on: September 21, 2018
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...