Finite element analysis of stress distribution at the tooth-denture base interface of acrylic resin teeth debonding
U R Darbar1, R Huggett, A Harrison
1Department of Oral and Dental Science, University of Wales College of Medicine, Cardiff, United Kingdom.
Abstract:
Acrylic resin teeth present a problem when they detach unexpectedly from the denture base resin. Detachment is caused by stress concentrations at the tooth/denture base resin interface. In this study, the finite element method was used to examine the stress distribution at this interface when a single static force that resembled incisal bite force was applied. The results indicated that irrespective of the type of acrylic resin teeth used, maximum tensile stresses were found at the palatal aspect of the interface. It is suggested that boxing the tooth in the acrylic resin will help redistribute stress concentrations favorably.
More Related Videos
Related Concept Videos
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes.
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and opposite to those on the...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Stress Concentrations
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Stress Concentrations
The stress concentration...