Related Experiment Video
Updated: Aug 12, 2026

A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Is image subtraction necessary in the clinical interpretation of single-day split-dose stress cerebral perfusion
C O Wong1, W J MacIntyre, E Q Chen
1Department of Nuclear Medicine, Cleveland Clinic Foundation, Cleveland, Ohio 44195 USA.
Abstract:
The aim of this study was to validate a simplified semiquantitative method of evaluating a single-day stress cerebral perfusion test to obtain cerebrovascular reserve capacity (CVRC) for routine clinical uses. A split-dose protocol was tested in 36 pairs of technetium-99m hexamethylpropylene amino oxime baseline (low dose) and acetazolamide (high dose) stress brain single-photon emission tomographic (SPET) studies from 16 patients with cerebrovascular disease. The images were displayed on a semiquantitative color scale with (corrected) and without (uncorrected) image subtraction, dose adjustment, and decay correction. The representative CVRC was determined by placing 3x3 pixel regions of interest on midthalamic and midcerebellar slices. The corrected and uncorrected relative changes in CVRC were correlated using linear regression. The relative changes of corrected (x) and uncorrected (y) CVRC by quantitative analysis were highly correlated in a linear fashion (y=0.67x+0.002, r=0.998, P<0.0005). As predicted by theory, the slope was related to the ratio of split dose and independent of ROI sampling. Single-day split-dose stress brain SPET can be accurately performed without image subtraction and complicated dose adjustment or decay correction for clinical studies.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Imaging Studies for Cardiovascular System V: CT

![Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F67458.jpg&w=3840&q=50)