Effect of tracheal gas insufflation on demand valve triggering and total work during continuous positive airway
J D Hoyt1, J J Marini, A Nahum
1University of Minnesota, Department of Pulmonary and Critical Care Medicine, St. Paul-Ramsey Medical Center, St. Paul, USA.
Abstract:
Tracheal gas insufflation (TGI) improves CO2 clearance and may reduce work of breathing by lowering the required minute ventilation (VE). However, TGI might also impair the ability to trigger the ventilator, because to lower external circuit pressures, inspiratory effort must outstrip catheter flow rate (Vc) and overcome the dynamic hyperinflation caused by TGI. We studied these effects using a two-chamber lung model of the respiratory muscles (RM) and lungs (L). The RM-chamber was ventilated using a sinusoidal flow pattern with a tidal volume (VT) of 0.5 L at various peak inspiratory flow rates (Vpk) to simulate differences in effort intensity. The L-chamber was connected to a 60-L/min continuous flow circuit with a 10 cm H2O positive end-expiratory pressure valve and to 3 different ventilatory demand valve circuits, each set at continuous positive airway pressure (CPAP) of 10 cm H2O. We used continuous TGI at 0, 2.5, 5, 10, and 15 L/min. The work of triggering (W-trig) increased with increasing Vc and decreased with increasing Vpk. The L-ventilator failed to trigger when Vc was 15 L/min and Vpk was 20 L/min. At a fixed VE, the effect of TGI on total mechanical inspiratory work (W-tot) was relatively small and varied among the different CPAP systems used. We conclude that weak patients may fail to open the demand valve of the CPAP system during TGI at high catheter flow rates. The net effect of TGI on the effort made by ventilated patients would depend not only on the interactions between TGI and the ventilator, but also on the efficiency of TGI in decreasing dead-space and lowering the VE requirement.
More Related Videos
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)